{"product_id":"3m™-8512-welding-n95-respirator-with-cool-flow™-valve","title":"3M™ 8512 Welding N95 Respirator with Cool Flow™ Valve","description":"\u003cp data-start=\"191\" data-end=\"553\"\u003eThe \u003cstrong data-start=\"195\" data-end=\"265\"\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003e3M\u003c\/span\u003e\u003c\/span\u003e™ 8512 Welding N95 Respirator\u003c\/strong\u003e is a NIOSH-approved N95 mask specifically designed for welding and metalworking applications. Engineered with flame-resistant outer shell material and a foam faceseal for enhanced comfort, this respirator provides reliable protection against certain welding fumes and solid particulates.\u003c\/p\u003e\n\u003cp data-start=\"555\" data-end=\"722\"\u003eWith its Cool Flow™ Exhalation Valve and adjustable buckle straps, the 8512 offers superior breathability and secure fit — ideal for demanding industrial environments.\u003c\/p\u003e\n\u003chr data-start=\"724\" data-end=\"727\"\u003e\n\u003ch2 data-section-id=\"1tm6yp4\" data-start=\"729\" data-end=\"750\"\u003eProduct Details\u003c\/h2\u003e\n\u003cp data-start=\"752\" data-end=\"1035\"\u003e\u003cstrong data-start=\"752\" data-end=\"769\"\u003eProduct Name:\u003c\/strong\u003e 3M™ 8512 Welding N95 Respirator\u003cbr data-start=\"801\" data-end=\"804\"\u003e\u003cstrong data-start=\"804\" data-end=\"817\"\u003eCategory:\u003c\/strong\u003e Respiratory Protective Equipment (PPE)\u003cbr data-start=\"856\" data-end=\"859\"\u003e\u003cstrong data-start=\"859\" data-end=\"868\"\u003eType:\u003c\/strong\u003e Disposable Welding Respirator\u003cbr data-start=\"898\" data-end=\"901\"\u003e\u003cstrong data-start=\"901\" data-end=\"911\"\u003eModel:\u003c\/strong\u003e 8512\u003cbr data-start=\"916\" data-end=\"919\"\u003e\u003cstrong data-start=\"919\" data-end=\"940\"\u003eProtection Level:\u003c\/strong\u003e N95\u003cbr data-start=\"944\" data-end=\"947\"\u003e\u003cstrong data-start=\"947\" data-end=\"973\"\u003eNIOSH Approval Number:\u003c\/strong\u003e TC-84A-0454\u003cbr data-start=\"985\" data-end=\"988\"\u003e\u003cstrong data-start=\"988\" data-end=\"1030\"\u003eOSHA Assigned Protection Factor (APF):\u003c\/strong\u003e 10\u003c\/p\u003e\n\u003chr data-start=\"1037\" data-end=\"1040\"\u003e\n\u003ch2 data-section-id=\"17fvu7l\" data-start=\"1042\" data-end=\"1060\"\u003eKey Features\u003c\/h2\u003e\n\u003cp data-start=\"1062\" data-end=\"1492\"\u003e✔ NIOSH Approved N95 Respirator\u003cbr data-start=\"1093\" data-end=\"1096\"\u003e✔ Minimum 95% filtration efficiency (non-oil aerosols)\u003cbr data-start=\"1150\" data-end=\"1153\"\u003e✔ Flame-resistant outer shell (modified ASTM D2859)\u003cbr data-start=\"1204\" data-end=\"1207\"\u003e✔ Designed for welding applications\u003cbr data-start=\"1242\" data-end=\"1245\"\u003e✔ Cake-resistant filter media\u003cbr data-start=\"1274\" data-end=\"1277\"\u003e✔ Foam faceseal for improved comfort \u0026amp; seal\u003cbr data-start=\"1320\" data-end=\"1323\"\u003e✔ Adjustable buckle straps for secure fit\u003cbr data-start=\"1364\" data-end=\"1367\"\u003e✔ 3M™ Cool Flow™ Exhalation Valve reduces heat buildup\u003cbr data-start=\"1421\" data-end=\"1424\"\u003e✔ Lightweight design (approx. 1.10 oz)\u003cbr data-start=\"1462\" data-end=\"1465\"\u003e✔ Latex-free construction\u003c\/p\u003e\n\u003chr data-start=\"1494\" data-end=\"1497\"\u003e\n\u003ch2 data-section-id=\"1awkj25\" data-start=\"1499\" data-end=\"1529\"\u003eRecommended Applications\u003c\/h2\u003e\n\u003cp data-start=\"1531\" data-end=\"1544\"\u003eSuitable for:\u003c\/p\u003e\n\u003cul data-start=\"1546\" data-end=\"1700\"\u003e\n\u003cli data-section-id=\"nu7brm\" data-start=\"1546\" data-end=\"1557\"\u003e\n\u003cp data-start=\"1548\" data-end=\"1557\"\u003eWelding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"162u1v\" data-start=\"1558\" data-end=\"1569\"\u003e\n\u003cp data-start=\"1560\" data-end=\"1569\"\u003eBrazing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1uq8fs2\" data-start=\"1570\" data-end=\"1598\"\u003e\n\u003cp data-start=\"1572\" data-end=\"1598\"\u003eCutting \u0026amp; heating metals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ad98rd\" data-start=\"1599\" data-end=\"1620\"\u003e\n\u003cp data-start=\"1601\" data-end=\"1620\"\u003eMetal fabrication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"5xuzjr\" data-start=\"1621\" data-end=\"1644\"\u003e\n\u003cp data-start=\"1623\" data-end=\"1644\"\u003eCertain metal fumes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"zf3dyq\" data-start=\"1645\" data-end=\"1667\"\u003e\n\u003cp data-start=\"1647\" data-end=\"1667\"\u003eSolid particulates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pg98vg\" data-start=\"1668\" data-end=\"1700\"\u003e\n\u003cp data-start=\"1670\" data-end=\"1700\"\u003eLiquid mists (non-oil based)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1702\" data-end=\"1719\"\u003e⚠ Do NOT use for:\u003c\/p\u003e\n\u003cul data-start=\"1720\" data-end=\"1864\"\u003e\n\u003cli data-section-id=\"k94fsv\" data-start=\"1720\" data-end=\"1739\"\u003e\n\u003cp data-start=\"1722\" data-end=\"1739\"\u003eGases or vapors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1knw5mg\" data-start=\"1740\" data-end=\"1756\"\u003e\n\u003cp data-start=\"1742\" data-end=\"1756\"\u003eOil aerosols\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"279m7a\" data-start=\"1757\" data-end=\"1769\"\u003e\n\u003cp data-start=\"1759\" data-end=\"1769\"\u003eAsbestos\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1k209qz\" data-start=\"1770\" data-end=\"1801\"\u003e\n\u003cp data-start=\"1772\" data-end=\"1801\"\u003eArsenic, cadmium, lead, MDA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1x5mce1\" data-start=\"1802\" data-end=\"1823\"\u003e\n\u003cp data-start=\"1804\" data-end=\"1823\"\u003eAbrasive blasting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"177e121\" data-start=\"1824\" data-end=\"1864\"\u003e\n\u003cp data-start=\"1826\" data-end=\"1864\"\u003eConcentrations exceeding 10x PEL\/OEL\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1866\" data-end=\"1869\"\u003e\n\u003ch2 data-section-id=\"x1lo0s\" data-start=\"1871\" data-end=\"1901\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1903\" data-end=\"2271\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1903\" data-end=\"1930\"\u003e\n\u003ctr data-start=\"1903\" data-end=\"1930\"\u003e\n\u003cth data-start=\"1903\" data-end=\"1919\" data-col-size=\"sm\" class=\"\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1919\" data-end=\"1930\" data-col-size=\"sm\" class=\"\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1959\" data-end=\"2271\"\u003e\n\u003ctr data-start=\"1959\" data-end=\"1994\"\u003e\n\u003ctd data-start=\"1959\" data-end=\"1975\" data-col-size=\"sm\"\u003eCertification\u003c\/td\u003e\n\u003ctd data-start=\"1975\" data-end=\"1994\" data-col-size=\"sm\"\u003eNIOSH 42 CFR 84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1995\" data-end=\"2050\"\u003e\n\u003ctd data-start=\"1995\" data-end=\"2019\" data-col-size=\"sm\"\u003eFiltration Efficiency\u003c\/td\u003e\n\u003ctd data-start=\"2019\" data-end=\"2050\" data-col-size=\"sm\"\u003e≥95% (Non-oil particulates)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2051\" data-end=\"2079\"\u003e\n\u003ctd data-start=\"2051\" data-end=\"2059\" data-col-size=\"sm\"\u003eValve\u003c\/td\u003e\n\u003ctd data-start=\"2059\" data-end=\"2079\" data-col-size=\"sm\"\u003eYes – Cool Flow™\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2080\" data-end=\"2122\"\u003e\n\u003ctd data-start=\"2080\" data-end=\"2099\" data-col-size=\"sm\"\u003eFlame Resistance\u003c\/td\u003e\n\u003ctd data-start=\"2099\" data-end=\"2122\" data-col-size=\"sm\"\u003eModified ASTM D2859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2123\" data-end=\"2151\"\u003e\n\u003ctd data-start=\"2123\" data-end=\"2132\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-start=\"2132\" data-end=\"2151\" data-col-size=\"sm\"\u003eApprox. 1.10 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2152\" data-end=\"2176\"\u003e\n\u003ctd data-start=\"2152\" data-end=\"2165\" data-col-size=\"sm\"\u003eShelf Life\u003c\/td\u003e\n\u003ctd data-start=\"2165\" data-end=\"2176\" data-col-size=\"sm\"\u003e3 Years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2177\" data-end=\"2227\"\u003e\n\u003ctd data-start=\"2177\" data-end=\"2199\" data-col-size=\"sm\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd data-start=\"2199\" data-end=\"2227\" data-col-size=\"sm\"\u003e-20°C to +30°C (\u0026lt;80% RH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2228\" data-end=\"2271\"\u003e\n\u003ctd data-start=\"2228\" data-end=\"2244\" data-col-size=\"sm\"\u003eLatex Content\u003c\/td\u003e\n\u003ctd data-start=\"2244\" data-end=\"2271\" data-col-size=\"sm\"\u003eNo natural rubber latex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp data-start=\"2273\" data-end=\"2298\"\u003e\u003cstrong data-start=\"2273\" data-end=\"2298\"\u003eMaterial Composition:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2299\" data-end=\"2527\"\u003e\n\u003cli data-section-id=\"rhnz00\" data-start=\"2299\" data-end=\"2350\"\u003e\n\u003cp data-start=\"2301\" data-end=\"2350\"\u003eStraps: Braided Polyisoprene \u0026amp; Cotton\/Polyester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"n9i0xn\" data-start=\"2351\" data-end=\"2377\"\u003e\n\u003cp data-start=\"2353\" data-end=\"2377\"\u003eBuckles: Polypropylene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tb6r3t\" data-start=\"2378\" data-end=\"2401\"\u003e\n\u003cp data-start=\"2380\" data-end=\"2401\"\u003eNose Clip: Aluminum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1dxpkko\" data-start=\"2402\" data-end=\"2424\"\u003e\n\u003cp data-start=\"2404\" data-end=\"2424\"\u003eFaceseal: PVC Foam\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"q7mnlq\" data-start=\"2425\" data-end=\"2450\"\u003e\n\u003cp data-start=\"2427\" data-end=\"2450\"\u003eFilter: Polypropylene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1crtq6q\" data-start=\"2451\" data-end=\"2487\"\u003e\n\u003cp data-start=\"2453\" data-end=\"2487\"\u003eShell: Flame-retardant Polyester\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"18ns2gz\" data-start=\"2488\" data-end=\"2527\"\u003e\n\u003cp data-start=\"2490\" data-end=\"2527\"\u003eValve: Polypropylene \u0026amp; Polyisoprene\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2529\" data-end=\"2532\"\u003e\n\u003ch2 data-section-id=\"to8ia\" data-start=\"2534\" data-end=\"2561\"\u003ePackaging Information\u003c\/h2\u003e\n\u003cul data-start=\"2563\" data-end=\"2635\"\u003e\n\u003cli data-section-id=\"1ihij6d\" data-start=\"2563\" data-end=\"2590\"\u003e\n\u003cp data-start=\"2565\" data-end=\"2590\"\u003eRespirators per Box: 10\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"nachoa\" data-start=\"2591\" data-end=\"2612\"\u003e\n\u003cp data-start=\"2593\" data-end=\"2612\"\u003eBoxes per Case: 8\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1eqkvxn\" data-start=\"2613\" data-end=\"2635\"\u003e\n\u003cp data-start=\"2615\" data-end=\"2635\"\u003eTotal per Case: 80\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2637\" data-end=\"2640\"\u003e\n\u003ch2 data-section-id=\"154e68f\" data-start=\"2642\" data-end=\"2680\"\u003eWhy Choose 3M™ 8512 Welding N95?\u003c\/h2\u003e\n\u003cp data-start=\"2682\" data-end=\"2747\"\u003eThe 8512 is purpose-built for welders and metalworkers requiring:\u003c\/p\u003e\n\u003cul data-start=\"2749\" data-end=\"2910\"\u003e\n\u003cli data-section-id=\"fa8hre\" data-start=\"2749\" data-end=\"2791\"\u003e\n\u003cp data-start=\"2751\" data-end=\"2791\"\u003eFlame-resistant respiratory protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"uqj7vu\" data-start=\"2792\" data-end=\"2823\"\u003e\n\u003cp data-start=\"2794\" data-end=\"2823\"\u003eComfortable long-shift wear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1mbnwef\" data-start=\"2824\" data-end=\"2848\"\u003e\n\u003cp data-start=\"2826\" data-end=\"2848\"\u003eReduced heat buildup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qd4ujt\" data-start=\"2849\" data-end=\"2880\"\u003e\n\u003cp data-start=\"2851\" data-end=\"2880\"\u003eNIOSH-certified performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"s321y4\" data-start=\"2881\" data-end=\"2910\"\u003e\n\u003cp data-start=\"2883\" data-end=\"2910\"\u003eOSHA-compliant protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2912\" data-end=\"3040\"\u003eIt is a trusted choice for fabrication shops, industrial plants, construction sites, and maintenance operations across Pakistan.\u003c\/p\u003e\n\u003chr data-start=\"3042\" data-end=\"3045\"\u003e\n\u003ch2 data-section-id=\"1st4gp\" data-start=\"3047\" data-end=\"3078\"\u003eSafety \u0026amp; Usage Guidelines\u003c\/h2\u003e\n\u003cul data-start=\"3080\" data-end=\"3317\"\u003e\n\u003cli data-section-id=\"gzhi3b\" data-start=\"3080\" data-end=\"3144\"\u003e\n\u003cp data-start=\"3082\" data-end=\"3144\"\u003eReplace when dirty, damaged, or difficult to breathe through\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"ci5elx\" data-start=\"3145\" data-end=\"3171\"\u003e\n\u003cp data-start=\"3147\" data-end=\"3171\"\u003eDo not alter or modify\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tr8une\" data-start=\"3172\" data-end=\"3210\"\u003e\n\u003cp data-start=\"3174\" data-end=\"3210\"\u003eFit testing recommended before use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"f7mx5k\" data-start=\"3211\" data-end=\"3249\"\u003e\n\u003cp data-start=\"3213\" data-end=\"3249\"\u003eNot suitable for IDLH environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"21ufk6\" data-start=\"3250\" data-end=\"3317\"\u003e\n\u003cp data-start=\"3252\" data-end=\"3317\"\u003eStore in original packaging away from sunlight and contaminants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"3M","offers":[{"title":"Default Title","offer_id":52375778427169,"sku":null,"price":0.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0975\/4381\/5457\/files\/Image.png?v=1771668576","url":"https:\/\/shalai.pk\/products\/3m%e2%84%a2-8512-welding-n95-respirator-with-cool-flow%e2%84%a2-valve","provider":"S. Halai","version":"1.0","type":"link"}